; vsphere虚拟机下的Linux在线移除硬盘后的报错处理(基于LVM) | Linux运维部落

vsphere虚拟机下的Linux在线移除硬盘后的报错处理(基于LVM)

1)故障描述( vmware虚拟机,在线移除一块被设置为pv格式的硬盘后,提示unknown device错误):

说明:/dev/sdb1 /dev/sdc1 /dev/sdd1是组成/dev/vg_test/lvm_test的PV,这里我们模拟/dev/sdd1硬盘被直接断电了

[root@docker mnt]# pvdisplay 
  /dev/sdd: read failed after 0 of 4096 at 0: Input/output error
  /dev/sdd: read failed after 0 of 4096 at 21474770944: Input/output error
  /dev/sdd: read failed after 0 of 4096 at 21474828288: Input/output error
  /dev/sdd: read failed after 0 of 4096 at 4096: Input/output error
  /dev/sdd1: read failed after 0 of 512 at 21467824128: Input/output error
  /dev/sdd1: read failed after 0 of 512 at 21467938816: Input/output error
  /dev/sdd1: read failed after 0 of 512 at 0: Input/output error
  /dev/sdd1: read failed after 0 of 512 at 4096: Input/output error
  /dev/sdd1: read failed after 0 of 2048 at 0: Input/output error
  Couldn't find device with uuid 166hLZ-2POl-GIsv-ELGh-8YVT-Zcoa-ZcLXzp.
  --- Physical volume ---
  PV Name               /dev/sdb1
  VG Name               vg_test
  PV Size               19.99 GiB / not usable 1.43 MiB
  Allocatable           yes (but full)
  PE Size               4.00 MiB
  Total PE              5118
  Free PE               0
  Allocated PE          5118
  PV UUID               fuQdIY-qkJw-fZJB-AauO-Zqpj-91RI-S1GG0X
   
  --- Physical volume ---
  PV Name               /dev/sdc1
  VG Name               vg_test
  PV Size               19.99 GiB / not usable 1.43 MiB
  Allocatable           yes 
  PE Size               4.00 MiB
  Total PE              5118
  Free PE               5116
  Allocated PE          2
  PV UUID               TRlpMQ-snM6-u24f-cMHa-oiVt-XJ3w-6fjAbp
   
  --- Physical volume ---
  PV Name               unknown device
  VG Name               vg_test
  PV Size               19.99 GiB / not usable 1.43 MiB
  Allocatable           yes 
  PE Size               4.00 MiB
  Total PE              5118
  Free PE               5118
  Allocated PE          0
  PV UUID               166hLZ-2POl-GIsv-ELGh-8YVT-Zcoa-ZcLXzp

2)处理步骤:

[root@docker mnt]# vgreduce --removemissing vg_test
  /dev/sdd: read failed after 0 of 4096 at 0: Input/output error
  /dev/sdd1: read failed after 0 of 2048 at 0: Input/output error
  /dev/sdd: read failed after 0 of 4096 at 21474770944: Input/output error
  /dev/sdd: read failed after 0 of 4096 at 21474828288: Input/output error
  /dev/sdd: read failed after 0 of 4096 at 4096: Input/output error
  /dev/sdd1: read failed after 0 of 512 at 21467824128: Input/output error
  /dev/sdd1: read failed after 0 of 512 at 21467938816: Input/output error
  /dev/sdd1: read failed after 0 of 512 at 0: Input/output error
  /dev/sdd1: read failed after 0 of 512 at 4096: Input/output error
  Couldn't find device with uuid 166hLZ-2POl-GIsv-ELGh-8YVT-Zcoa-ZcLXzp.
  Wrote out consistent volume group vg_test
[root@docker mnt]# vgchange -a y
  /dev/sdd: read failed after 0 of 4096 at 0: Input/output error
  /dev/sdd1: read failed after 0 of 2048 at 0: Input/output error
  1 logical volume(s) in volume group "vg_test" now active
[root@docker mnt]# df -h
Filesystem            Size  Used Avail Use% Mounted on
/dev/sda3             193G   14G  170G   8% /
tmpfs                 1.9G  228K  1.9G   1% /dev/shm
/dev/sda1             190M   80M  100M  45% /boot
/dev/mapper/vg_test-lvm_test
                       20G   28M   19G   1% /mnt

测试表明:整个过程都不会影响/mnt中的数据运行

[root@docker mnt]# pvdisplay 
  /dev/sdd: read failed after 0 of 4096 at 0: Input/output error
  /dev/sdd: read failed after 0 of 4096 at 21474770944: Input/output error
  /dev/sdd: read failed after 0 of 4096 at 21474828288: Input/output error
  /dev/sdd: read failed after 0 of 4096 at 4096: Input/output error
  /dev/sdd1: read failed after 0 of 512 at 21467824128: Input/output error
  /dev/sdd1: read failed after 0 of 512 at 21467938816: Input/output error
  /dev/sdd1: read failed after 0 of 512 at 0: Input/output error
  /dev/sdd1: read failed after 0 of 512 at 4096: Input/output error
  /dev/sdd1: read failed after 0 of 2048 at 0: Input/output error
  --- Physical volume ---
  PV Name               /dev/sdb1
  VG Name               vg_test
  PV Size               19.99 GiB / not usable 1.43 MiB
  Allocatable           yes (but full)
  PE Size               4.00 MiB
  Total PE              5118
  Free PE               0
  Allocated PE          5118
  PV UUID               fuQdIY-qkJw-fZJB-AauO-Zqpj-91RI-S1GG0X
   
  --- Physical volume ---
  PV Name               /dev/sdc1
  VG Name               vg_test
  PV Size               19.99 GiB / not usable 1.43 MiB
  Allocatable           yes 
  PE Size               4.00 MiB
  Total PE              5118
  Free PE               5116
  Allocated PE          2
  PV UUID               TRlpMQ-snM6-u24f-cMHa-oiVt-XJ3w-6fjAbp

发现仍旧有I/O的错误出现,找到合适停机窗口,重启了系统,故障得到解决(这里注意重启前检查fstab信息,看下mount -a是否有报错)。

[root@docker ~]# pvdisplay 
  --- Physical volume ---
  PV Name               /dev/sdb1
  VG Name               vg_test
  PV Size               19.99 GiB / not usable 1.43 MiB
  Allocatable           yes (but full)
  PE Size               4.00 MiB
  Total PE              5118
  Free PE               0
  Allocated PE          5118
  PV UUID               fuQdIY-qkJw-fZJB-AauO-Zqpj-91RI-S1GG0X
   
  --- Physical volume ---
  PV Name               /dev/sdc1
  VG Name               vg_test
  PV Size               19.99 GiB / not usable 1.43 MiB
  Allocatable           yes 
  PE Size               4.00 MiB
  Total PE              5118
  Free PE               5116
  Allocated PE          2
  PV UUID               TRlpMQ-snM6-u24f-cMHa-oiVt-XJ3w-6fjAbp

这样,系统就已经没有报错信息了。

原创文章,作者:Net21-冰冻vs西瓜,如若转载,请注明出处:/26670

联系我们

400-080-6560

在线咨询:点击这里给我发消息

邮件:1660809109@qq.com

工作时间:周一至周五,9:30-18:30,节假日同时也值班

友情链接:万达娱乐平台  万达娱乐主管QQ  万达娱乐主管QQ  万达主管  华宇招商  万达招商  万达娱乐主管  万达娱乐注册  万达娱乐开户  万达娱乐招商